PROCEDURES FOR RFP VOLTAGE ADJUSTMENT

ON DTP-16HC-1

 

1.      Install DTP-16HC-1 to KTS or PBX system

2.      Make sure normal display appears on LCD display

3.      Remove Handset from Base Unit.

4.      Unplug Line Cord

5.      Press 0 and 9 Key at the same time while inserting the line cord

6.      Release the 0 and 9 Key

7.      The display should now say RFP Test

8.      Press the 1 Key

9.      Press #*#*

10.  Press the Speaker Key

11.  Press Line Key 4

12.  Press the Speaker Key

13.  D/D Voltage should read E6, E7, E8 or E9  OK

Note: E6-E9 values are okay for this D/D Voltage setting

 

14. Press the Up Volume Key once

15.  Press Dial Key 1

16.  Press #*#*

17.  Press the Speaker Key

18.  Press Line Key 5

19.  Press the Speaker Key

20.  CHG Voltage should read E6, E7, E8 or E9  OK

Note: E6-E9 values are okay for this CHG Voltage setting

 

21.  Now press the Up Volume Key once

22.  Press the Hold Key and return the Handset to the Base Unit. This will

Complete the RFP test process. Please note: The Display may go Blank for approx 1 sec as the Base unit returns back to the normal operating mode.

 

Process Complete