IPK II Timers – General
By default all phones and all trunks are in timer class 0. When in class 0 they follow the system timers. If you assign a phone or a trunk to timer class 1~15 then they do not follow the system timers they follow the timers in 20-31-XX.
20-29-01 Assign extensions to a timer class 1~15 per DAY/NIGHT mode
20-30-01 Assign trunks to a timer class 1~15 per DAY/NIGHT mode
Below are some of the common system and class timers:
|
TIMER |
SYSTEM |
CLASS |
|
Delay Call Forward (Call Forward BNA) |
24-02-03 |
20-31-15 |
|
Hold Recall Timer |
24-01-01 |
20-31-10 |
|
Hold Recall Call Back Time (Trunk) |
24-01-02 |
20-31-11 |
|
Exclusive Hold Recall Timer |
24-01-03 |
20-31-12 |
|
Excl. Hold Recall Callback Time (Trunk) |
24-01-04 |
20-31-13 |
|
Call Park Recall |
24-01-06 |
20-31-14 |
|
Extended Call Park Recall (20-11-19) |
24-01-07 |
NONE (24-01-07) |
|
Transfer Recall |
24-02-04 |
20-31-16 |
|
DIL No Answer Timer (Trunk Based) |
22-01-04 |
20-31-08 |
|
CAR/SIE/Virtual Delay Ring |
20-04-03 |
20-31-03 |
|
|
|
|